<?xml version="1.0" encoding="ISO-8859-1"?>
<rss version="2.0">
  <channel>
    <title>DVTk (Main) :: Forum</title>
    <link>http://www.dvtk.org/</link>
    <description>Explore the new dimension of Integration Testing :: XOOPS Community Bulletin Board</description>
    <lastBuildDate>Sat, 25 May 2013 19:56:27 +0200</lastBuildDate>
    <docs>http://backend.userland.com/rss/</docs>
    <generator>CBB 3.08</generator>
    <category>Forum</category>
    <managingEditor>dvtk@dvtk.org</managingEditor>
    <webMaster>dvtk@dvtk.org</webMaster>
    <language>en</language>
        <image>
      <title>DVTk (Main) :: Forum</title>
      <url>http://www.dvtk.org/modules/newbb/images/xoopsbb_slogo.png</url>
      <link>http://www.dvtk.org/</link>
      <width>92</width>
      <height>52</height>
    </image>
            <item>
      <title>&quot;FR&quot; not accepted as value in Patient Orientation [by ldepotter]</title>
      <link>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=600&amp;forum=20</link>
      <description>DVT:: &quot;FR&quot; not accepted as value in Patient Orientation&lt;br /&gt;
Hi,&lt;br /&gt;&lt;br /&gt;When I send a mammography image for presentation to DVT with a L-MLO view I get an error stating that the “Patient Orientation” (0020,0020) which has the value “A”,”FR” is incorrect. FR is apparently for part of the list of enumerated values.&lt;br /&gt;However, DICOM states in part 3 C.7.6.1.1.1 Patient Orientation that:&lt;br /&gt;&lt;br /&gt;For Patient Orientation each value of the orientation attribute shall contain at least one of the abbreviations. If refinements in the orientation descriptions are to be specified, then they shall be designated by one or two additional abbreviations in each value. Within each value, the abbreviations shall be ordered with the principal orientation designated in the first abbreviations.&lt;br /&gt;&lt;br /&gt;See also note 2 that states:&lt;br /&gt;&lt;br /&gt;E.g., a medio-lateral oblique projection of the left breast of a human might be encoded with Patient Orientation values of “A\FR” rather than “A\F”, since the plane is obliquely inclined such that the colums are directed both downwards and medially, which for a left breast is towards the right, though the downwards direction is the principal column orientation.&lt;br /&gt;&lt;br /&gt;Is there a way to work around this problem in DVT?&lt;br /&gt;&lt;br /&gt;Best regards &lt;br /&gt;&lt;br /&gt;Ludo</description>
      <pubDate>Mon, 25 Mar 2013 11:08:23 +0200</pubDate>
      <guid>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=600&amp;forum=20</guid>
    </item>
        <item>
      <title>Shutter Shape = Bitmap indicated as wrong in DVT [by ldepotter]</title>
      <link>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=598&amp;forum=20</link>
      <description>DVT:: Shutter Shape = Bitmap indicated as wrong in DVT&lt;br /&gt;
Hi,&lt;br /&gt;&lt;br /&gt;When I send a Grayscale Softcopy Presentation State object to DVT, containing a Bitmap Display Shutter Module (To hide the background of a mammo image), then DVT give’s me back an error that has to do with the &amp;quot;Display Shutter Module&amp;quot;. &lt;br /&gt;DVT complains that 0018,1600 Shutter Shape hast the wrong value (= Bitmap).&lt;br /&gt;&lt;br /&gt;Below this, in the &amp;quot;Bitmap Display Shutter Module&amp;quot; the same attribute 0018,1600 Shutter Shape with value =Bitmap is indicated as correct. (As expected)&lt;br /&gt;&lt;br /&gt;Is this a known problem?&lt;br /&gt;&lt;br /&gt;Best regards,&lt;br /&gt;&lt;br /&gt;Ludo</description>
      <pubDate>Mon, 18 Mar 2013 15:41:48 +0200</pubDate>
      <guid>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=598&amp;forum=20</guid>
    </item>
        <item>
      <title>Re: VOI LUT Sequence Question [by ldepotter]</title>
      <link>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=571&amp;forum=20</link>
      <description>DVT:: VOI LUT Sequence Question&lt;br /&gt;
Hi Marco,&lt;br /&gt;&lt;br /&gt;Did someone already create a ticket for this problem and if yes, what is the status today?&lt;br /&gt;&lt;br /&gt;Regards,&lt;br /&gt;&lt;br /&gt;Ludo</description>
      <pubDate>Mon, 18 Mar 2013 12:24:20 +0200</pubDate>
      <guid>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=571&amp;forum=20</guid>
    </item>
        <item>
      <title>cannot get pass on failed storage commitment SCP response [by fschroeck]</title>
      <link>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=597&amp;forum=20</link>
      <description>DVT:: cannot get pass on failed storage commitment SCP response&lt;br /&gt;
Hello,&lt;br /&gt;to test our StorageCommitmentSCP we would like to validate the response if the storage commitment fails. The script is attached.&lt;br /&gt;The problem is, that even if the response is negative, DVT wants the ReferencedSOPSequence. In our research in the DICOM standard we came across PS 3.4-2008, Page 174.:&lt;br /&gt;&quot;When a response is negative the field &quot;Referenced SOP Sequence&quot;, is not mandatory and should be present only when there is any positive match&quot;&lt;br /&gt;&lt;br /&gt;But when running the script, the result is &quot;failed&quot; and DVT says:&lt;br /&gt;&quot;Type 1 (mandatory) attribute (0008,1199) should be present with at least one value.&quot;&lt;br /&gt;&lt;br /&gt;I have tried the latest DVT version 2.6.8. Is this a bug in DVT or a problem in our script?&lt;br /&gt;&lt;br /&gt;Thank you very much!</description>
      <pubDate>Thu, 07 Mar 2013 12:26:10 +0200</pubDate>
      <guid>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=597&amp;forum=20</guid>
    </item>
        <item>
      <title>Re: MPPS Media Validation Failure to recognize SOP Class [by marcokemper]</title>
      <link>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=596&amp;forum=20</link>
      <description>DVT:: MPPS Media Validation Failure to recognize SOP Class&lt;br /&gt;
&lt;p&gt;Hi,&lt;/p&gt;&lt;p&gt;according to DICOM, you can only store SOP instances from storage SOP classes in DICOM files. DVTk is able to validate the content of exactly these DICOM files.&lt;/p&gt;&lt;p&gt;You are trying to validate a MPPS message that has been stored in a pseudo-DICOM file, created by DVTk. This is &lt;u&gt;not&lt;/u&gt; a DICOM file according to the DICOM standard. DVTk supports storing MPPS messages in pseudo-DICOM files to be able to store the data set part of a MPPS message for reuse in e.g. test scripts. And as this is not a valid DICOM file as specified by the DICOM standard, DVTk is not able to validate this and you will get the error messages as described by you.&lt;/p&gt;&lt;p&gt;&amp;nbsp;&lt;/p&gt;&lt;p&gt;Regards,&lt;br /&gt;Marco&lt;/p&gt;&lt;p&gt;&amp;nbsp;&lt;/p&gt;</description>
      <pubDate>Thu, 07 Mar 2013 08:26:55 +0200</pubDate>
      <guid>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=596&amp;forum=20</guid>
    </item>
        <item>
      <title>Re: Trying to build DVTk on windows 7 [by marcokemper]</title>
      <link>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=594&amp;forum=20</link>
      <description>DVT:: Trying to build DVTk on windows 7&lt;br /&gt;
Hi David,&lt;br /&gt;&lt;br /&gt;thanks for letting other people know the space problem so fast.&lt;br /&gt;&lt;br /&gt;Regards,&lt;br /&gt;Marco</description>
      <pubDate>Thu, 07 Feb 2013 10:24:30 +0200</pubDate>
      <guid>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=594&amp;forum=20</guid>
    </item>
        <item>
      <title>Re: Problem with PRINT-SCP [by Mikhail]</title>
      <link>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=567&amp;forum=20</link>
      <description>DVT:: Problem with PRINT-SCP&lt;br /&gt;
Hey!&lt;br /&gt;&lt;br /&gt;I&#039;m new to DVT scripting and I received the same error message. It happened while trying to test the C-FIND command using DVT as SCP and a DICOM workstation as SCU. I used the following script :&lt;br /&gt;&quot;&lt;br /&gt;RECEIVE ASSOCIATE-RQ(&lt;br /&gt;	PRESENTATION-CONTEXT-ITEMS&lt;br /&gt;	(&quot;1.2.840.10008.5.1.4.1.2.2.1&quot;, &quot;Implicit VR Little Endian&quot;, &quot;Explicit VR Little Endian&quot;, &quot;Explicit VR Big Endian&quot; )&lt;br /&gt;)&lt;br /&gt;&lt;br /&gt;SEND ASSOCIATE-AC(&lt;br /&gt;	PRESENTATION-CONTEXT-ITEMS&lt;br /&gt;	(&quot;1.2.840.10008.5.1.4.1.2.2.1&quot;, 0, &quot;Implicit VR Little Endian&quot;)&lt;br /&gt;)&lt;br /&gt;&lt;br /&gt;RECEIVE C-FIND-RQ &quot;Study Root Query/Retrieve - FIND&quot;(&lt;br /&gt;	(0x00000002, &quot;1.2.840.10008.5.1.4.1.2.2.1&quot;)&lt;br /&gt;	(0x00000110, 0x0001)&lt;br /&gt;&lt;br /&gt;	(0x00080052, &quot;STUDY&quot;)&lt;br /&gt;	(0x00100020, &quot;IS000789&quot;)&lt;br /&gt;	(0x0020000D, &quot;&quot;)&lt;br /&gt;)&lt;br /&gt;&lt;br /&gt;SEND C-FIND-RSP &quot;Study Root Query/Retrieve - FIND&quot;(&lt;br /&gt;	(0x00000002, &quot;1.2.840.10008.5.1.4.1.2.2.1&quot;)&lt;br /&gt;	(0x00000120, 0x0001)&lt;br /&gt;	(0x00000900, 0xFF00)&lt;br /&gt;	&lt;br /&gt;	(0x00080052, &quot;STUDY&quot;)&lt;br /&gt;	(0x00080054, &quot;DVT&quot;)&lt;br /&gt;	(0x00100020, &quot;IS000789&quot;)&lt;br /&gt;	(0x0020000D, &quot;CT&quot;)&lt;br /&gt;)&lt;br /&gt;&lt;br /&gt;SEND C-FIND-RSP &quot;Study Root Query/Retrieve - FIND&quot;(&lt;br /&gt;	(0x00000002, &quot;1.2.840.10008.5.1.4.1.2.2.1&quot;)&lt;br /&gt;	(0x00000120, 0x0001)&lt;br /&gt;	(0x00000900, 0x0000)&lt;br /&gt;)&lt;br /&gt;	&lt;br /&gt;RECEIVE RELEASE-RQ&lt;br /&gt;&lt;br /&gt;SEND RELEASE-RP&lt;br /&gt;&quot;&lt;br /&gt;&lt;br /&gt;and received those errors :&lt;br /&gt;&lt;br /&gt;&quot;...&lt;br /&gt;VALIDATE C-FIND-RQ Study Root Query/Retrieve - FIND &lt;br /&gt;Against reference Command: C-FIND-RQ &lt;br /&gt;Against reference Dataset: Study Root Query/Retrieve - FIND &lt;br /&gt;C-FIND-RQ&lt;br /&gt;&lt;br /&gt;Error: No Command and/or Dataset definition found - validation skipped&lt;br /&gt;Link to Summary Result &lt;br /&gt;&lt;br /&gt;Error: No Dataset definition found - no validation done&lt;br /&gt;Link to Summary Result &lt;br /&gt;&lt;br /&gt;Error: Name: &quot;DICOM&quot; Version: &quot;3.0&quot;&lt;br /&gt;Link to Summary Result &lt;br /&gt;Association open 0.03 seconds &lt;br /&gt;&quot;&lt;br /&gt;&lt;br /&gt;Could anyone help me finding out where does the error come from? It&#039;s probably a simple error, but as I said, I just started to write my first DICOM scripts.&lt;br /&gt;&lt;br /&gt;Regards</description>
      <pubDate>Wed, 18 Jul 2012 11:06:20 +0200</pubDate>
      <guid>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=567&amp;forum=20</guid>
    </item>
        <item>
      <title>Re: SendQueryModalityWorklist(TagValueCollection queryTags); [by davidf]</title>
      <link>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=578&amp;forum=20</link>
      <description>DVT:: SendQueryModalityWorklist(TagValueCollection queryTags);&lt;br /&gt;
I figured it out, so don&amp;#039;t bother. thanks!</description>
      <pubDate>Wed, 16 May 2012 22:16:34 +0200</pubDate>
      <guid>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=578&amp;forum=20</guid>
    </item>
        <item>
      <title>Re: System.OutOfMemoryException when trying to validate .dcm file [by marcokemper]</title>
      <link>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=569&amp;forum=20</link>
      <description>DVT:: System.OutOfMemoryException when trying to validate .dcm file&lt;br /&gt;
&lt;p&gt;Hi,&lt;/p&gt;&lt;p&gt;thanks for letting us know what caused the problem! &lt;/p&gt;&lt;p&gt;Correct attribute lengths specified in a DICOM file and DICOM message is normally&amp;nbsp;critical for correct interpretation of the stream. Depending on the implementation, some applications may handle incorrect attribute length better than other applications.&lt;/p&gt;&lt;p&gt;Trying to recover from these kind of problems is something we already keep in mind if we would decide to create a new architecture/implementation for the coding and encoding of a DICOM stream.&lt;/p&gt;&lt;p&gt;Regards,&lt;/p&gt;&lt;p&gt;Marco&lt;/p&gt;&lt;p&gt;&amp;nbsp;&lt;/p&gt;</description>
      <pubDate>Tue, 13 Mar 2012 13:30:45 +0200</pubDate>
      <guid>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=569&amp;forum=20</guid>
    </item>
        <item>
      <title>Re: Definiton file for Breast Tomo. Storage [by marcokemper]</title>
      <link>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=570&amp;forum=20</link>
      <description>DVT:: Definiton file for Breast Tomo. Storage&lt;br /&gt;
&lt;p&gt;LS,&lt;/p&gt;&lt;p&gt;thisis an easy one to answer &lt;img src=&quot;/uploads/smil3dbd4d4e4c4f2.gif&quot; border=&quot;0&quot; alt=&quot;&quot; width=&quot;17&quot; height=&quot;17&quot; /&gt;.&lt;/p&gt;&lt;p&gt;It is already part of the definition files version 1.1.10. &lt;/p&gt;&lt;p&gt;Maybe it just has not&amp;nbsp;been loaded yet. In which application(s) do you want to use this definition file?&lt;/p&gt;&lt;p&gt;Regards,&lt;br /&gt;Marco Kemper&lt;/p&gt;&lt;p&gt;&amp;nbsp;&lt;/p&gt;</description>
      <pubDate>Thu, 16 Feb 2012 16:12:55 +0200</pubDate>
      <guid>http://www.dvtk.org/modules/newbb/viewtopic.php?topic_id=570&amp;forum=20</guid>
    </item>
      </channel>
</rss>